universal ac input low leakage current 0.3ma protections: short circuit / overload / over voltage fixed switching frequency at 45khz cooling by free air convection model number output volts output amps ovp volt tolerance dc volt adjust effciency single output mps65-3.3 3.3 volts(dc) 12 amps 3.8~4.46volts(dc) 3.0% 2.97~3.63volts(dc) 66% mps65-5 5.0 volts(dc) 12 amps 5.75~6.75volts(dc) 3.0% 4.5~5.5volts(dc) 74% mps65-7.5 7.5 volts(dc) 8.0 amps 8.63~10.1volts(dc) 3.0% 6.75~8.25volts(dc) 76% mps65-12 12 volts(dc) 5.2 amps 13.8~16.2volts(dc) 2.0% 10.8~13.2volts(dc) 77% mps65-13.5 13.5 volts(dc) 4.7 amps 15.5~18.2volts(dc) 2.0% 12.2~14.85volts(dc) 78% mps65-15 15 volts(dc) 4.2 amps 17.25~20.25volts(dc) 2.0% 13.5~16.5volts(dc) 79% mps65-24 24 volts(dc) 2.7 amps 27.6~32.4volts(dc) 2.0% 21.6~26.4volts(dc) 80% mps65-27 27 volts(dc) 2.4 amps 31~36.45volts(dc) 2.0% 24.3~29.7volts(dc) 80% mps65-48 48 volts(dc) 1.35 amps 55.2~64.8volts(dc) 2.0% 43.2~52.8volts(dc) 80% 65w single output for medical type mps65 series www.astrodynetdi.com astrodyne usa: 1-800-823-8082 astrodyne pacific: 886-2-26983458
input specifications input voltage range 90-264vac / 127-370 volts(dc) frequency range 47-440 hz inrush current, typ: (cold start) 15amps @ 115vac input 30 amps @ 230vac input current 1.6 amps max @ 115vac 0.9 amps max @ 230vac leakage current < 0.3ma / 264 vac output specifications voltage and current see selection chart line regulation 1.0% load regulation 3.0%: 3.3~7.5volts(dc) 2.0%: 12~48volts(dc) voltage tolerance (note 2) see selection chart ripple/noise (note 1) 80mvpk-pk: 3.3volts(dc): 100mvpk-pk: 5~48volts(dc) hold up time @ fl 50ms @ 230vac 16ms @ 115vac setup, rise time @ fl 800ms, 30ms/230vac 800ms. 30ms/115vac over voltage protection see selection chart hiccup mode, auto recover over current protection 73~105w rated output power hiccup mode, auto recover dc volt adjust see selection chart general specifications safety ul2601-1 tuv en60601-1 i e c 6 0 6 0 1 - 1 a p p r o v e d insulation resistance 100m? emi compliance to en55011(cispr11) class b harmonic current compliance to en61000-3-2,-3 effciency see selection chart isolation 4000vac input - output 1500vac input - ground 500vac output - ground ems compliance to en61000-4-2,3,4,5,6,8,11; env50204, en55024, en60601-1-2, medical level, criteria a environmental specifications oper. temperature -10c to +60c (see derate curve) storage temperature -20c to +85c, 10~95% rh relative humidity 20 to +90% rh non cond temperature coeffcient 0.04% / c (0-50c) on +5v output mtbf 359.7khrs min,mil-udbk-217f(-25c) vibration 10~500hz, 2g10min./1cycle, period for 60min. each along x, y, z axes physical specifications size millimeters 127 x 76 x 42 inches 5 x 2.99 x 1.65 weight 8.11 oz (230g) note 1. ripple and noise are measured at 20mhz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1uf & 47 uf parallel capacitor . 2. tolerance: includes set up tolerance, line regulation and load regula - tion. 3. mounting holes m1 and m2 should be grounded for emi purposes. all specifcations are typical at nominal input, full load, and 25c unless other - wise noted 65w single output for medical type mps65 series www.astrodynetdi.com astrodyne usa: 1-800-823-8082 astrodyne pacific: 886-2-26983458
65w single output for medical type mps65 series www.astrodynetdi.com astrodyne usa: 1-800-823-8082 astrodyne pacific: 886-2-26983458
65w single output for medical type mps65 series www.astrodynetdi.com astrodyne usa: 1-800-823-8082 astrodyne pacific: 886-2-26983458
|